| ProductsServiceCompanyNewsContact |
|
|
> >
Air-Circulation Bench Type Furnace KU 15/06/A Air-circulation Chamber Furnaces KU 40/04/A – KU 540/08/A T max 450 °C, 650 °C and 850 °C - Air-circulation chamber furnaces up to 850 °C, mainly used for annealing, tempering, ageing, pre-heating, drying, shrinking, baking, testing
- Rugged casing construction made of high-grade steel sheets
- Swinging door hinged on the right
- Inner liner of heat-resistant stainless steel > Long service life, extremely resilient, corrosion resistant
- 2 sheet-metal trays included as standard (KU 15/06/A without trays, for 850 °C models sheet metal trays as option)
- High-grade heating elements with long service life
- Heating from several sides, powerful horizontal air circulation > Excellent temperature uniformity up to +/-3 K in accordance with DIN 17052
- High-grade insulation > Low energy consumption, low operating costs
- Base included in standard supply (KU 15/06/A as bench-type furnace without base)
|
|
|
Technical Data
| Model |
T max
[°C] |
Inside dimensions
[mm]
[width x depthx height] |
Volume
[l] |
Outside dimensions
[mm]
[width x depth x height] |
Power
[kW] |
Voltage
[V] |
Weight
[kg] |
| KU 40/04/A |
450 |
300 x 400 x 300 |
35 |
540 x 1050 x 1270 |
3,2 |
230 1/N |
115 |
| KU 70/04/A |
450 |
350 x 500 x 400 |
70 |
590 x 1150 x 1370 |
6,4 |
400 3/N |
130 |
| KU 140/04/A |
450 |
450 x 600 x 500 |
135 |
690 x 1250 x 1470 |
9,6 |
400 3/N |
205 |
| KU 270/04/A |
450 |
600 x 750 x 600 |
270 |
840 x 1450 x 1620 |
12,8 |
400 3/N |
370 |
| KU 540/04/A |
450 |
750 x 900 x 800 |
540 |
990 x 1600 x 1820 |
19,2 |
400 3/N |
540 |
| |
|
|
|
|
|
|
|
| KU 15/06/A |
650 |
300 x 350 x 150 |
15 |
500 x 900 x 440 |
2,4 |
230 1/N |
50 |
| KU 40/06/A |
650 |
300 x 400 x 300 |
35 |
540 x 1050 x 1270 |
4,0 |
400 3/N |
125 |
| KU 70/06/A |
650 |
350 x 500 x 400 |
70 |
590 x 1150 x 1370 |
8,0 |
400 3/N |
140 |
| KU 140/06/A |
650 |
450 x 600 x 500 |
135 |
690 x 1250 x 1470 |
12,0 |
400 3/N |
220 |
| KU 270/06/A |
650 |
600 x 750 x 600 |
270 |
830 x 1560 x 1610 |
16,0 |
400 3/N |
390 |
| KU 540/06/A |
650 |
750 x 900 x 800 |
540 |
990 x 1600 x 1820 |
24,0 |
400 3/N |
560 |
| |
|
|
|
|
|
|
|
| KU 40/08/A |
850 |
300 x 400 x 300 |
35 |
850 x 1360 x 1470 |
6,0 |
400 3/N |
290 |
| KU 70/08/A |
850 |
350 x 500 x 400 |
70 |
900 x 1460 x 1570 |
10,0 |
400 3/N |
360 |
| KU 140/08/A |
850 |
450 x 600 x 500 |
135 |
1000 x 1560 x 1670 |
14,0 |
400 3/N |
580 |
| KU 270/08/A |
850 |
600 x 750 x 600 |
270 |
1150 x 1710 x 1770 |
20,0 |
400 3/N |
770 |
| KU 540/08/A |
850 |
750 x 900 x 800 |
540 |
1300 x 1860 x 1970 |
30,0 |
400 3/N |
920 |
* Width without control panel (+260 mm), height incl. frame · Charging height: approx. 900 mm
Options: Air circulation furnaces are used for many different applications. The available options meet the specific requirements for the desired heat treatment process. We also supply all furnaces in customized dimensions on request.
Automatic exhaust flap control Enables exhaust flap to be operated via controller
Air extraction Ensures fast venting of the furnace chamber
Cooling fan For flushing and for forced cooling of the batch
Inert gas connection and sealing Prepares furnace for semi-gastight operation
Furnace operation with inert gas retort Annealing and tempering under inert gas, cooling under inert gas, superb results, bright surfaces almost without oxidation
Lift door With pneumatic drive, operated by foot or hand switch
Charging supports Charging wagon, shown here with a stainless-steel rack, for safe and convenient charging
|
|
|
Air-circulation Chamber Furnaces KM 1000/06/A - KM 2000/08/A T max 650 °C and 850 °C- Air-circulation chamber furnaces designed for heavy industrial applications with charging weights of more than several tonnes
- Rugged casing construction made of high-grade steel sheets
- Standard furnace door designed as hinged door
- Inner liner of heat-resistant stainless steel > Long service life, extremely resilient, corrosion resistant
- High-grade heating elements with long service life
- Heating from several sides, powerful horizontal air circulation > Excellent temperature uniformity up to +/-7 K in accordance with DIN 17052
- Optimal air circulation by means of air outlets, adapted to the charge
- High-grade insulation > Low energy consumption, low operating costs
Options:- Hydraulic lifting door
- Automatic control of exhaust flaps
- Powerful cooling system
- Furnace in semi-gastight version with inert-gas connection for operation with protective gases
- Customised designs made to order
|
|
 - KM 2000/06/A - Chamber furnace with hydraulic lift door
|
Technical Data (Other sizes on request)
| Model |
T max
[°C] |
Inside dimensions
[mm]
[width x depth x height] |
Volume
[l] |
Outside dimensions
[mm]
[width x depth x height] |
Power
[kW] |
Voltage
[V] |
Weight
[kg] |
| KM 1000/06/A |
650 |
1000 x 1000 x 1000 |
1000 |
2300 x 2100 x 3200 |
36 |
400 3/N |
1300 |
| KM 1500/06/A |
650 |
1500 x 1000 x 1000 |
1500 |
2800 x 2100 x 3200 |
48 |
400 3/N |
1500 |
| KM 2000/06/A |
650 |
2000 x 1000 x 1000 |
2000 |
3400 x 2100 x 3200 |
72 |
400 3/N |
1750 |
| |
|
|
|
|
|
|
|
| KM 1000/08/A |
850 |
1000 x 1000 x 1000 |
1000 |
2400 x 2200 x 3300 |
42 |
400 3/N |
1300 |
| KM 1500/08/A |
850 |
1500 x 1000 x 1000 |
1500 |
2900 x 2200 x 3300 |
54 |
400 3/N |
1500 |
| KM 2000/08/A |
850 |
2000 x 1000 x 1000 |
2000 |
3500 x 2200 x 3300 |
80 |
400 3/N |
1750 |
|