home  ι  impressem
 
 

Muffle/chamber furnaces

Compact Muffle Furnace
T max 1000 °C
  • Compact muffle furnace with outstanding price-performance ratio
  • Suitable for maximum temperature up to 1000 °C
  • User-friendly swing door
  • Insulation completely made of high grade ceramic fibre with low thermal mass for fast heating cycles
  • Heating elements wound around outside of ceramic muffle, heating from all sides
  • Heating elements controlled by solid state relays for very precise temperature control, wear-free and noiseless
  • Exhaust pipe in the rear wall

Accessories:
  • Vent
  • Adjustable temperature limiter to protect furnace and charge acc. EN 60519-2
  • Further accessories see furnace accessories
 
Kompakt-Muffelofen
Kompakt-Muffelofen

Technical Data

Model T max
[°C]
Inner dimensions
[mm]
[Width x Depth x Height]
Volume
[l]
Outer dimensions
[mm]
[Width x Depth x Height]
Power
[kW]
Voltage
[V]
Weight
[kg]
KLS 03/10 1000 140 x 200 x 110 3 320 x 350 x 410 1,5 230 V 1/N 20
Muffle Furnaces
T max 1100 °C and 1200 °C
  • Universal muffle furnaces for ambitious laboratory applications
  • Compact design for minimum space requirements
  • Stainless steel casing, long service life, extremely resistant
  • Resistant fibre module as inner chamber, high mechanical durability, short heating cycles, low power consumption
  • Door collar made of strong fire bricks to protect insulation against mechanical damages
  • High-quality heating elements, long service life
  • Heating wire embedded in ceramic plates with good protection against damages, service-friendly and cost-effective
  • Heating elements controlled by solid state relays for very precise temperature control, wear-free and noiseless
  • Exhaust pipe in the rear wall

Accessories:
  • Vent with / without fan
  • Vent with fan and catalytic converter
  • Adjustable temperature limiter to protect furnace and charge acc. EN 60519-2
  • Further accessories see furnace accessories
 
Muffelöfen

Technical Data

Model T max
[°C]
Inner dimensions
[mm]
[Width x Depth x Height]
Volume
[l]
Outer dimensions
[mm]
[Width x Depth x Height]
Power
[kW]
Voltage
[V]
Weight
[kg]
KL 03/11 1100 180 x 140 x 100 3 380 x 415 x 400 1,2 230 V 1/N 20
KL 05/11 1100 230 x 170 x 130 5 430 x 445 x 425 2,4 230 V 1/N 35
KL 09/11 1100 230 x 240 x 170 9 430 x 515 x 465 3,0 230 V 1/N 45
KL 15/11 1100 250 x 340 x 170 15 450 x 615 x 465 3,5 230 V 1/N 50
               
KL 03/12 1200 180 x 140 x 100 3 380 x 415 x 400 1,2 230 V 1/N 20
KL 05/12 1200 230 x 240 x 170 5 430 x 445 x 425 2,4 230 V 1/N 35
KL 09/12 1200 250 x 340 x 170 9 430 x 515 x 465 3,0 230 V 1/N 45
KL 15/12 1200 250 x 340 x 170 15 450 x 615 x 465 3,5 230 V 1/N 50
Laboratory Chamber Furnaces
T max 1100 °C, 1200 °C and 1300 °C
  • Very high temperature uniformity inside the furnace chamber
  • Double-walled housing with rear-ventilation to ensure low outer-casing temperatures
  • Parallel-guided door moving up-wards with hot insulation surface to the rear, away from operator
  • Insulation made of high grade ceramic fibre with low thermal mass
  • Door collar made of strong fire bricks
  • Wear-resistant fire brick insulation in the furnace bottom
  • Delivery includes ceramic bottom plate
  • Heating elements on ceramic supporting tubes, mounted in front of the insulation for free heat radiation
  • Powerful heating elements in both sides providing fast heating rates
  • Heating elements controlled by solid state relays for very precise temperature control, wear-free and noiseless
  • Exhaust pipe in the rear wall
 
Labor-kammeröfen

Technical Data

Model T max
[°C]
Inner dimensions
[mm]
[Width x Depth x Height]
Volume
[l]
Outer dimensions
[mm]
[Width x Depth x Height]
Power
[kW]
Voltage
[V]
KLS 05/11 1100 210 x 200 x 150 6 550 x 580 x 650 2,0 230 V 1/N
KLS 10/11 1100 200 x 250 x 200 10 560 x 670 x 720 3,0 230 V 1/N
KLS 15/11 1100 220 x 300 x 230 15 560 x 670 x 720 4,0 400 V 2/N
KLS 30/11 1100 280 x 380 x 280 30 590 x 700 x 790 4,0 400 V 2/N
KLS 45/11 1100 300 x 500 x 300 45 660 x 720 x 770 6,0 400 V 3/N
             
KLS 05/12 1200 180 x 200 x 140 5 550 x 580 x 650 2,0 230 V 1/N
KLS 10/12 1200 200 x 250 x 200 10 560 x 670 x 720 4,0 400 V 2/N
KLS 15/12 1200 220 x 300 x 230 15 560 x 670 x 720 4,0 400 V 2/N
KLS 30/12 1200 280 x 350 x 280 27 590 x 700 x 790 4,5 400 V 3/N
KLS 45/12 1200 300 x 500 x 300 45 660 x 720 x 770 6,0 400 V 3/N
             
KLS 05/13 1300 200 x 250 x 140 7 550 x 580 x 650 2,5 230 V 1/N
KLS 10/13 1300 200 x 250 x 180 9 560 x 670 x 720 4,0 400 V 2/N
KLS 15/13 1300 230 x 300 x 230 16 560 x 670 x 720 4,0 400 V 2/N
KLS 30/13 1300 270 x 350 x 270 26 590 x 700 x 790 6,0 400 V 3/N
KLS 45/13 1300 300 x 500 x 300 45 660 x 720 x 770 6,0 400 V 3/N
Laboratory Chamber Furnaces

Wide range of furnaces
THERMCONCEPT laboratory chamber funaces are available in sizes from 5 litres to 45 litres (see Technical Data). The inner dimensions and maximum operating temperatures are adapted to the needs of laboratories. Our range of furnaces also includes models with a Voltage of 230 V.







Accessories
Due to many different accessories and extras our laboratory chamber furnaces can be adapted to individual needs and applications:
  • Vent with / without fan
  • Vent with fan and catalytic converter
  • Adjustable temperature limiter to protect furnace and charge acc. EN 60519-2
  • Protective gas connection at the rear side
  • Further accessories see furnace accessories




With moveable bottom
Laboratory chamber furnaces can be also supplied with manually moveable furnace bottom to charge the bottom easily outside the furnace. Available for all chamber furnaces with a temperature range up to 1100 °C, 1200 °C and 1300 °C.



With integrated air circulation
Laboratory chamber furnaces can be supplied optional with fan for integrated air circulation. This air circulation system increases heat transfer from heating elements to the charge and temperature uniformity inside the chamber. Chamber furnaces with integrated air circulation are available for a maximum temperature of 1100 °C.
 
Labor-Kammeröfen
Zusatzt-Austattung abzug
Zusatzt-Austattung gasventil
Labor-Kammeröfen mit ausfahrbarem Ofenboden