Special furnace up to 1100 °CChamber furnace for testing fire protection plates and fire protection glass. Up to 1000 °C in 10 minutes. Thickness of test plates between 25 - 100 mm. Max. temperature up to 1400 °C and slight over pressure are optional available. Chamber furnace with protective gas atmosphere up to 1700 °CChamber furnace with water cooled, gas tight chamber. The furnace canbe used up to 1700 °C with protective gas atmosphere. An oxygen sensor monitors the O2-content in the exhaust gas. To increase the purity of the atmosphere, a vacuum pump can be used to evacuate the chamber before starting the process. Furnaces up to 2000 °CFor a temperature range up to 2000 °C in normal atmosphere a special furnace series has been developed. Typical areas for such furnaces are high temperature reaction studies, sintering of advanced ceramics, melting and pouring of special glasses etc. Available as chamber-, lift-bottom or tube furnaces.
Apparatus for Hot Modulus of Rupture (HMOR) testsThis furnace system was developed to investigate the hot modulus of rupture of new refractory materials. The furance has a maximum temperature of 1600°C. The gas tight design allows different gas atmospheres to be used. The oxygen partial pressure is monitored online through an oxygen sensor. A walking beam system is installed so that 6 samples can be introduced simultaneously. The transport of the samples is semi-automatic. A sample size of 25 x 25 x 150 mm can be tested according to the three-point-bending method. All relevant process and experimental data are registered by the software supplied.
|